Product details
Downloads
Documents
Drawings
-
2D DWG Topvnd.dwg
-
3D DWGvnd.dwg
-
2D DWG frontvnd.dwg
-
2D DWG rightvnd.dwg
-
3D STPplain
-
PDFpdf
-
2D DWG Top
Product photos
-
Article imagejpeg
-
Article image
Accessories
recommended
7945725 - Commissioning Cat. 3
Service description:
commissioning category 3 for a standard system in the product ranges Reflexomat Compact RSC / Servitec S / Reflex Hydroflow mains water station by Customer Service comprising:
While it is entirely possible for customers to put a recently purchased system into service themselves, there are a number of reasons why commissioning by Reflex is a better idea.
the service can take place within the local country inside about three weeks, internationally within about six weeks after placing of the corresponding order.
Services provided by Service are net! The price does not include any site waiting times or work arising from improper installation or improper condition.
Programming of the expansion and bus modules does not form part of commissioning. Programming is billed separately based on time and expenditure.
commissioning category 3 for a standard system in the product ranges Reflexomat Compact RSC / Servitec S / Reflex Hydroflow mains water station by Customer Service comprising:
- Travel to and from site,
- Setting of the system to the operating parameters specified by the customer,
- Checking the settings and operating parameters, and the system's performance and function in the overall system,
- Fillsoft and Fillset are also checked
- All set values are documented in a log.
- electrical and hydraulic connection of the control unit, the accessory components and filled supply system.
- The expansion vessels of the pressurisation station must not be filled with water.
- A sufficient supply of filling water must be provided.
While it is entirely possible for customers to put a recently purchased system into service themselves, there are a number of reasons why commissioning by Reflex is a better idea.
- Certainty that the system is set up for optimum operation
- Excluding of possible damage due to incorrect commissioning thus reliability and avoidance of time and costs for downtimes
the service can take place within the local country inside about three weeks, internationally within about six weeks after placing of the corresponding order.
Services provided by Service are net! The price does not include any site waiting times or work arising from improper installation or improper condition.
Programming of the expansion and bus modules does not form part of commissioning. Programming is billed separately based on time and expenditure.
optional
7613100 - Cap valve SU G1" × 1"
Cap valve
For diaphragm expansion vessels in sealed heating and cooling systems.With a safe shut-off to prevent inadvertent closing and a discharge according to DIN EN 12828.
For diaphragm expansion vessels in sealed heating and cooling systems.With a safe shut-off to prevent inadvertent closing and a discharge according to DIN EN 12828.
optional
9119352 - motorized ball valve Safecontrol
Safecontrol
Motor ball valve as conversion kit for water make-up in conjunction with Servitec and Variomat.Actuation takes place directly from the control unit. The dirt-resistant motor ball valve is spring-closed without any need for an electrical supply.Hydraulic and electrical connections must be made on-site.
Motor ball valve as conversion kit for water make-up in conjunction with Servitec and Variomat.Actuation takes place directly from the control unit. The dirt-resistant motor ball valve is spring-closed without any need for an electrical supply.Hydraulic and electrical connections must be made on-site.
optional
7945726 - Commissioning add. Cat. 3
Service description:
commissioning of an additional system, category 3, for a standard system in the product ranges Reflexomat Compact RSC / Servitec S / Reflex Hydroflow by the customer service, comprising:
commissioning of an additional system, category 3, for a standard system in the product ranges Reflexomat Compact RSC / Servitec S / Reflex Hydroflow by the customer service, comprising:
- Adjustment of system to the operating parameters specified by the client,
- Checking the settings and operating parameters, and the system's performance and function in the overall system,
- Fillsoft and Fillset are checked too
- All set values documented in a report.
- electrical and hydraulic connection of the control unit, the accessory components and filled supply system.
- The expansion vessels of the pressurisation station must not be filled with water.
- A sufficient supply of filling water must be provided.
optional
7857700 - diaphragm rupture detector MBM II
Membrane rupture detector
Electrode with evaluation relay for installation in an expansion vessel with an appropriate connection. Vessel must be pre-equipped for electrode (please note when ordering)
Electrode with evaluation relay for installation in an expansion vessel with an appropriate connection. Vessel must be pre-equipped for electrode (please note when ordering)
Inclusive of electrode relay for signal measurement for installation in installer-supplied control cabinet or for local installation.
- power supply 230 V/50 Hz
- floating output (changeover contact)
Contact the Reflex Team and further information
Reflex Solutions Pro
- Free to use
- Simple and self-explanatory
- Detailed documentation
:focal(1994x788:1995x789))
Reflex Solutions Pro allows you to design every Reflex and Sinus product into your project quickly and easily. After entering a few system parameters you will receive your custom product solution with all the relevant documentation.
:focal(2087x741:2088x742))
:focal(1743x771:1744x772))
:focal(2030x752:2031x753))
:focal(2016x687:2017x688))
)
:focal(1976x799:1977x800))
:focal(2178x616:2179x617))
:focal(1769x919:1770x920))
:focal(1794x960:1795x961))
:focal(1688x825:1689x826))
:focal(2211x774:2212x775))
:focal(2197x762:2198x763))
:focal(2012x887:2013x888))
:focal(2042x677:2043x678))
:focal(1964x703:1965x704))
:focal(2004x771:2005x772))
:focal(2129x802:2130x803))
:focal(1842x717:1843x718))
:focal(2252x541:2253x542))
:focal(2028x656:2029x657))
:focal(2216x805:2217x806))
:focal(1757x521:1758x522))
:focal(1995x840:1996x841))
:focal(1426x934:1427x935))
:focal(2162x651:2163x652))
:focal(1922x670:1923x671))
:focal(2171x571:2172x572))
:focal(1493x511:1494x512))
:focal(2073x622:2074x623))
:focal(1908x623:1909x624))
:focal(1797x799:1798x800))
:focal(1029x706:1030x707))
:focal(1889x1023:1890x1024))
:focal(1973x660:1974x661))
:focal(1897x1028:1898x1029))
:focal(1899x1038:1900x1039))
:focal(1895x1017:1896x1018))
:focal(924x891:925x892))
:focal(2030x451:2031x452))
:focal(2098x769:2099x770))
:focal(2026x319:2027x320))
:focal(1743x810:1744x811))
:focal(1397x785:1398x786))
:focal(2044x818:2045x819))
:focal(1842x700:1843x701))