Article image
Article images
Article images
Article image
Article images
Article images

Item no.: 9583531

Reflex Hydroflow XS - CU

thermostatic freshwater station

Technical data

Type

XS - CU

Primary content

0.74 l

Secondary content

0.59 l

Fire protection class according to DIN 4102

B2

Housing material

null

Fire behaviour class according to EN 13501-1 (WBI)

F

Material of connecting parts on heating side

SST

Material of connecting parts on potable water side

SST + ME

Heat exchanger material

CU

Insulation material

EPP

Sealing material

paper

Charge pump

Grundfos UPM4 15-70 CZA (Solar-PWM)

Power consumption of pump

52 W

Volume flow sensor

Flow switch 12V, from 1.3 l/min

Perm. operating temperature on heater side

2 - 95 °C

Perm. operating overpressure on heating side

1 - 10 bar

Perm. operating overpressure on heating water side

1 - 10 bar

Max. pressure loss on potable water side

0.877 bar

Max. pressure loss in the pipework on the heating side

50 mbar

Nominal width on heater side / potable on water side

DN20

Electric connection

230V/50Hz

Connection heating side

G 1"

Connection potable water side

G 1"

Nominal capacity at KW-WW HVL 10-45°C/65°C

60.0 kW

Tap capacity 10-45°C/65°C

25 l/min

NL number according to DIN4708

3.47

Nominal capacity at KW-WW HVL 10-60°C/75°C

67 kW

Tap capacity 10-60°C/75°C

19 l/min

Nominal capacity at KW-WW HVL 10-60°C/75°C mixed to 45°C WW

64.8 kW

Tap capacity 10-60°C/75°C mixed to 45°C WW

27 l/min

Heating surface

0.8 m²

Height

185 mm

Width

350 mm

Length

425 mm

Weight

8.31 kg

EAN code

4036705445859

Product details

Reflex Hydroflow
Ready-assembled and cabled mains water station with thermostatic control, ready for hygienic heating of potable water. Equipped with a Reflex plate heat exchanger (copper-brazed) with perfectly matched thermal length for low return temperatures, which works based on the counter-flow principle. Stainless steel pipework. Fittings made of brass.

Downloads

Accessories

optional
Article image

9583551 - Reflex Hydroflow Ball valve set individual station XS / S / M

Reflex Hydroflow ball valve set
comprising three ball valves for wall mounting of the station or if no Reflex Storaflow pipe connection set has been ordered.

DN 20 ball valves for heating side flow/return Rp 3/4" - 1" male thread and hot water RP 3/4" - union not 1” thread.

optional
Article image

9583563 - Reflex Hydroflow Heating water mixer

Reflex Hydroflow Heating Water Mixer
for installation in systems with high buffer temperatures, in the buffer flow to the mains water station. Used to add colder heating water from the buffer tank from a colder layer in order to reduce the flow temperature in the mains water station and therefore achieve an even higher control quality of the hot water, preferably to be used in systems with solar thermal energy or solid fuel boilers, for example.
optional
Article image

7945725 - Commissioning Cat. 3

Service description:
commissioning category 3 for a standard system in the product ranges Reflexomat Compact RSC / Servitec S / Reflex Hydroflow mains water station by Customer Service comprising:
  • Travel to and from site,
  • Setting of the system to the operating parameters specified by the customer,
  • Checking the settings and operating parameters, and the system's performance and function in the overall system,
  • Fillsoft and Fillset are also checked
  • All set values are documented in a log.

Requirements:

  • electrical and hydraulic connection of the control unit, the accessory components and filled supply system.
  • The expansion vessels of the pressurisation station must not be filled with water.
  • A sufficient supply of filling water must be provided.

Customer benefits:
While it is entirely possible for customers to put a recently purchased system into service themselves, there are a number of reasons why commissioning by Reflex is a better idea.

  • Certainty that the system is set up for optimum operation
  • Excluding of possible damage due to incorrect commissioning thus reliability and avoidance of time and costs for downtimes

Commissioning date:
the service can take place within the local country inside about three weeks, internationally within about six weeks after placing of the corresponding order.
Services provided by Service are net! The price does not include any site waiting times or work arising from improper installation or improper condition.
Programming of the expansion and bus modules does not form part of commissioning. Programming is billed separately based on time and expenditure.

optional
Article image

7945726 - Commissioning add. Cat. 3

Service description:
commissioning of an additional system, category 3, for a standard system in the product ranges Reflexomat Compact RSC / Servitec S / Reflex Hydroflow by the customer service, comprising:
  • Adjustment of system to the operating parameters specified by the client,
  • Checking the settings and operating parameters, and the system's performance and function in the overall system,
  • Fillsoft and Fillset are checked too
  • All set values documented in a report.

Requirements:

  • electrical and hydraulic connection of the control unit, the accessory components and filled supply system.
  • The expansion vessels of the pressurisation station must not be filled with water.
  • A sufficient supply of filling water must be provided.

Contact the Reflex Team and further information

Reflex Solutions Pro

  • Free to use
  • Simple and self-explanatory
  • Detailed documentation
Reflex Solutions Pro

Reflex Solutions Pro allows you to design every Reflex and Sinus product into your project quickly and easily. After entering a few system parameters you will receive your custom product solution with all the relevant documentation.